HU-LIFT

Err38

  • Follow below video and check if cables are broken, or cables connection is cut or loose.

    Cause of failure: communication failure between handle and controller

    Tools: multimeter; allen wrench; phillips screwdriver

    Checking method:

    1. Check if the connection of handle cable and truck body communication cable is loose

    2. Check if handle cable and truck body cable is broken (if visual inspection can not detect the issue, then multimeter is needed to do testing)

    3. If the above causes are ruled out, most likely controller or monitor is faulty


Step1: Check if handle cable and truck body cables are loose

Check cable appearance

Step2: Check if handle cable and truck body cables are broken

Check the continuity of each cable with multimeter

Copyright © 2023 HU-LIFT Spain Ltd. All rights reserved.